shopping cart |
article
GO
GO

UST 08 V 80 G3-T4

Ultrasonic Sensor

  • Narrow detection beam / small blind zone
  • Switching functions: NO/NC, frame function teachable
  • Insensitive to dirt
  • Small design
  • Stainless steel casing
  • Protection class IP 67
UST 08 V 80 G3-T4 - Ultrasonic Sensor
Photo
Drawing
Connection diagram
TECHNICAL INFORMATION (typ.) +20°C, 24V DC
Operating principle Ultrasonic sensor
Evaluation digital
Size M8 x 1 (thread)
Design screw
Sending axis axial
Nominal switching distance (Sn) 80 mm
Standardized measuring plate 10 x 10 mm
Service voltage 18 ... 30 V DC
No-load current < 22 mA, (24 V DC)
Operating distance 20 ... 80 mm adjustable
Sensitivity adjustment Remote teach
Switching output Push pull, 150 mA, NO/NC, switchable
Max. power operating 150 mA
Switching hysteresis 5 %
Sound frequency 470 kHz
Display LED yellow (Display output)
Voltage drop < 2,5 V
Switching frequency 12 Hz
Reproducibility < 0,3 mm
Readiness delay < 300 ms
Ambient temperature, operation 0 … +50 °C
Insulation voltage endurance 500 V
Protection class IP 67
Protection degree III, operation on protective low voltage
Casing material V2A (1.4305 / AISI 303)
Material epoxy resin, PUR (Transducer surface)
Connection Connector, M8, 4-poled
di-soric Layout